Modern solar modules are robust, but not invincible. Degradation—the natural aging of the cells—averages 0.4 to 0.8% per year. This means that after 10 years, the original performance can drop by up to 8%, depending on the technology, quality, and site conditions.

How targeted tests provide clarity – and prepare for repowering.

Photovoltaic systems run reliably—often for decades. But over the years, their yield declines. The cause? Degradation, defects, or simply technical progress. Those who know their old system can retrofit it in a targeted manner, upgrade it economically, or simply make its performance visible again. But how much is really left in the modules? And when is replacement worthwhile?

Why performance is lost

Modern solar modules are robust, but not invulnerable. Degradation—the natural aging of the cells—averages 0.4 to 0.8% per year. This means that after 10 years, the original output can drop by up to 8%, depending on the technology, quality, and location conditions.

But it's not always just natural causes:

Glass damage caused by hail, frost, or stress cracks can weaken modules, sometimes drastically, and can even pose safety risks. Often, this damage goes undetected until there is a noticeable drop in yield.
Glass damage caused by hail, frost, or stress cracks can weaken modules, sometimes drastically, and can even pose safety risks. Often, this damage goes undetected until there is a noticeable drop in yield.

Mechanical damage such as broken glass can lead to a sudden drop in performance – a clear case for replacement.

Glass damage caused by hail, frost, or stress cracks can weaken modules, sometimes drastically, and can even pose safety risks. Often, this damage goes undetected until there is a noticeable drop in yield.

Typical causes of poor performance:

  • Cell aging & delamination

  • Back breaks or fine cell cracks

  • Microcracks caused by mechanical influences

  • Potential Induced Degradation (PID)

  • Pollution or shading

Professional maintenance and inspection of a commercial PV system – regular checks of solar modules, wiring, and inverters for maximum system availability and optimal energy yields.

Contamination reduces yield in the long term – a flash test shows whether cleaning or repowering is worthwhile. Pollen, bird droppings, industrial emissions – even light films of dirt reduce light absorption and thus electricity yield. Many operators underestimate this insidious effect.

Hotspots – the invisible power guzzlers

Hot spots occur when individual areas of cells overheat significantly—usually due to cracks, soldering errors, or shading. These thermal anomalies can not only reduce yield, but also shorten the service life of the modules in the long term. Thermography or flash tests can be used to detect hot spots in a targeted manner.

Hotspots occur when individual cell areas overheat significantly – usually due to cracks, soldering defects, or shading. These thermal anomalies can not only negatively impact yield but also shorten the module's lifespan in the long run. An inspection using thermography or a flash test makes hot spots visible.

A so-called hotspot – often the result of cell damage or selective shading – can not only reduce yield, but also place a thermal load on neighboring modules.

How can this be verified?

A mobile flash test allows the condition of each individual module to be analyzed in detail. The performance is measured under standardized conditions (STC) and compared with the original data – directly on site.

Flash Test Defective Solar Module

Check specifically – instead of replacing everything

Replacing old modules completely is costly—but not always necessary. Often, it is worth selective Repowering:

  • Only replace weak modules

  • Use more powerful modules

  • Increase overall yield through targeted modernization

Lightning strikes can damage modules or inverters – often unnoticed. An inspection protects against unpleasant surprises. Such damage often remains hidden during visual inspections. Only during electrical testing does it become apparent whether modules have been affected – a clear case for the mobile flash test.

Lightning strikes can damage modules or inverters – often without being noticed. An inspection protects against unpleasant surprises. Such damage often remains hidden during visual inspections. Only an electrical inspection reveals whether modules have been damaged – a clear case for the mobile flash test.

Particularly relevant for commercial roofs

Large commercial roof systems in particular often have enormous untapped potential. Here, Distact Energy offers a special service:

✅ disassembly
✅ Mobile flash tests
✅ Evaluation & consulting
✅ Modernization upon request

This allows operators to know exactly which modules are still performing – and where specific upgrades can be made. No unnecessary investments, with a complete basis for decision-making.

Good to know:

Did you know that some older solar modules still deliver over 85% of their rated output after more than 20 years? Others, however, fall below 75% after just 10 years. A flash test shows the difference – and protects you from premature investments or permanent loss of yield.

Your PV system deserves more than mere estimates.
We show you what it really has to offer – precisely, straightforwardly, and on site.